ACDSV acoustical smoke vent designed to guard against noise intrusion while providing the security of automatic smoke venting
February 7, 2022
BILCO's ACDSV acoustical smoke vent is designed to guard against noise intrusion while providing the security of automatic smoke venting. Acoustical vents feature industry-high STC 50 and OITC-46 sound ratings. They are ideal for concert halls, theaters and other interior applications that require limited noise from the outside. Vents are available in steel construction and in a number of UL-Listed standard sizes.
Automatic Acoustical Smoke Vent
Type ACDSV
Standard Features and Benefits
-
STC-50, OITC 46, and ISO 140-18 (rain fall - 37.5 db) sound ratings. (Read selecting the proper sound rating for Automatic Smoke Vents)
- Thermolatch® II positive hold/release mechanism ensures reliable vent operation when a fire occurs.
- Automatically releases vent covers upon the melting of a UL-listed 165°F (74°C) fusible link.
- The curb-mounted fusible link housing allows the latch to be quickly and easily reset from the roof level.
- Engineered with powerful gas spring operators to open covers in snow and wind conditions.
- Gas springs have integral dampers to assure the covers open at a controlled rate.
- Fully insulated and gasketed for weather-tightness.
- Constructed with corrosion resistant materials to provide many years of trouble free, dependable service.
- Available in a number of standard UL listed sizes.
Guide Specifications
- Material: Cover is 14 gauge (2 mm) G-90 paint bond galvanized steel.
- Covers: Brakeformed, hollow-metal design with 4" (100 mm) mineral wool insulation, 5-3/4" (146 mm) beaded, overlapping flange, fully welded at corners, and internally reinforced for 40 psf (195 kg/m2) live load.
- Curb: 12" (305mm) in height with integral capflashing, 4" (100 mm) fiberboard insulation, fully welded at corners, and 6-7/8" (175mm) mounting flange with 7/16" holes (11mm) provided for securing frame to the roof deck.
- Gasket: Extruded PVC gaskets permanently adhered to the underside of the cover and the top of the curb.
- Hinges: Heavy-duty pintle hinges with 3/8" (9 mm) type 316 stainless steel hinge pins.
- Latch: Positive hold/release mechanism controlled by a single UL-listed 165°F (74°C) fusible link with a separate latching point for each cover. Designed to hold the covers closed against a 90 psf (438kg/m2) wind uplift force. Provided with interior and exterior pull release cables to manually open vent covers.
- Operation: When acoustical smoke vent is released, high performance gas springs open covers against a 10 psf (49kg/m2) snow/wind load and lock covers in the open position. Gas springs have integral dampers to assure a controlled rate of cover opening and have a cyclic durability of 50,000 cycles.
- Performance Ratings: STC-50, OITC 46, and ISO 140-18 (rain fall - 37.5 db) sound ratings. UL-listed.
- Comply with UL 793 and UL 790 Class A (burning brand test).
- Finish: Alkyd base red oxide primer.
- Hardware: Corrosion-resistant gas springs and hot dip galvanized steel stop cables. All other hardware is zinc plated/chromate sealed.
Automatic Smoke Vents - Protecting Life & Property
Automatic smoke vents aide fire fighting efforts and promote safe building evacuation by removing heat, smoke, and toxic fumes from a burning building. Watch our short video on the theory behind automatic smoke ventilation and learn how to protect your property and its contents.
Case Studies
- Cincinnati Music Hall
- DICK Cold Storage
- Great Lakes Center for the Arts
- Hale Centre Theatre
- McCain Auditorium at Kansas State University
- McKinney National Business Park
- Middlesex School
- New Brunswick Performing Arts Center
- PromoWest Pavilion at Ovation
- The Gordy Theater
- Upper Arlington High School
@TheBilcoCompany #TheBilcoCompany #flooraccess #roofhatches #smokevents #basementdoors
Company: Bilco
Source: https://www.bilco.com/oitc
Tags:
Access Control
Access Covers
Window Wells add natural daylight to any underground space (September 13, 2021), Fall Protection Grating for Floor Access Doors (December 7, 2020), 5 Questions With Jim Edgeworth, Residential Sales Director for The BILCO Company (August 31, 2020), Custom Period-Matched Perforated Grilles (June 12, 2020), Automatic Smoke Vents (January 27, 2020), Roof hatches, smoke vents and fall protection (August 28, 2019), Floor access doors for finished flooring (July 30, 2019), Spring forward with basement door maintenance: after rough winter, take steps now to evaluate and tend to your entryway (April 3, 2019), Tree grilles and floor access covers at The Wintergarden (February 27, 2019), Floor access covers for flexible floor finish (January 30, 2019)
Acoustics
The Most Attractive Temporary Office Wall Systems (December 10, 2021)
Entrances
Fire Resistant
Hurricane
National Preparedness Month: Hurricane Protection (September 24, 2021), Impact resistant entrances: introducing the 350/500 IR Water Performance Option, a watertight option from Kawneer (August 13, 2021), The EconoSpan® louver and screen system is ideal for roof top equipment screening or other applications with large areas requiring concealment and ventilation (April 30, 2021), Designing for Resilience: Hurricane Protection (September 14, 2020), Building Peace of Mind with Hurricane Resistant Solutions (September 9, 2020), Wind-driven, rain resistant stationary louvers (May 18, 2020), Hurricane Protection Systems (November 4, 2019), Specialty Shape Louvers (December 3, 2018), Data center protection (April 15, 2018), Sto launches impact resistance program (September 4, 2017)
Safety
Ventilation
Ventilating the top and bottom of a cavity wall (October 27, 2021), Ventilating the top and bottom of a cavity wall (August 4, 2021), How 3D Printing is Helping the Coronavirus Cause (July 2, 2021), The Daylighting Difference: Restaurants (June 23, 2021), The EconoSpan® louver and screen system is ideal for roof top equipment screening or other applications with large areas requiring concealment and ventilation (April 30, 2021), What are the Steps for Creating a Dynamic Wall? (April 14, 2021), STC or OITC? How to select the proper sound rating for automatic smoke vents (February 3, 2021), New Advanced Thermal Dispersion Airflow Measurement System Flyer (November 20, 2019), Benefits of specifying complete masonry veneer wall systems (January 23, 2019)