Fire rated door and frame assemblies

February 7, 2023

Read the full original article here >

Fire resistance is the property of a material (such as insulation) or assembly of materials to withstand fire, continue to perform its given function and/or provide containment of a fire for a specified period, and prevent the fire from spreading. The occupancy level, building type and egress requirements based on national, state, and local codes will dictate the use of many more fire rated openings throughout most of these buildings. So, what exactly is a fire-rated door, and how is it different from any other door in your building?

Fire rated door and frame assemblies

A fire-rated door is an interior or exterior fire door designed to stop the spread of fire and allow inhabitants to quickly and easily get to safety. The fire resistance rating of their frame, door, and hardware defines fire-rated doors. All fire-rated openings need to be tested and certified  by independent laboratories compliant with the  national fire safety standards and building codes, with fire labels issued to manufacturer’s under licensing programs for their application and use.

An architect determines the best places for fire doors to be installed to ensure that they are compliant with all levels of codes. Another purpose of fire doors is the creation of passive fire safety systems, which save lives by stopping the progress of destructive fires. Fire doors are rated to the duration of time that they will not combust or fail in the event of a fire based on the results of strict laboratory testing.  Standard fire ratings typically range from 20 minutes to 180 minutes.

Fire-rated door assemblies play an important role in saving lives and minimizing property damage by providing safe egress and compartmentalizing smoke, flames and when required, dangerous radiant heat. This is a combination of the door, frame, hardware, and glazing working together as one assembly. These components are normally tested as separate products by a nationally recognized testing agency and then listed, labeled, or classified for use in fire door assemblies. However, there are instances where specific components are tested together, and therefore must be used together in order to maintain the fire rating.

Fire door assemblies are tested to NFPA 252, Standard Methods of Fire Tests of Door Assemblies or UL 10 B, Standard for Fire Tests of Door Assemblies, or UL 10 C, Standard for Positive Pressure Fire Tests of Door Assemblies.  Like fire window assemblies, fire door assembly testing includes the fire endurance test and hose stream test. Note that building codes throughout the US and Canada typically stipulate that 20-minute doors are exempt from the hose stream test.

The basic requirements for fire rated door assemblies include:

  • Fire ratings (20/45/60/90/180 minutes) are granted by third-party testing agencies and are labeled on the products.
  • Fire rated door assemblies must meet the requirements of the applicable building or life safety code, such as the National Fire Protection Association (NFPA) 80: Standard for Fire Doors and Other Opening Protectives, NFPA 101: Life Safety Code, the International Building Code (IBC)and the International Fire Code (IFC).
  • Fire doors are required to be self-closing and positive latching.
  • The fire rating of the wall dictates the fire rating of the door. However, it is important to note that 2-hour fire rated wall requires a 90-minute fire rated door opening and likewise a 1-hour fire rated wall requires a 45-minute fire rated opening.
  • A fire rated opening is part of a building’s passive fire protection system that provides two distinct functions: reduce the spread of fire and/or smoke and enable safe egress from the building in the event of a fire.
  • For an opening to qualify as fire rated, all components including the door, frame, glass and glazing, hardware* and any required gasketing must be listed with an agency with laboratory that is in compliance with NFPA Standards 80 and 101, building codes and any ordinances.
  • There are two exceptions for a fire rated opening. Kick plates below 16 inches tall do not require labeling, and until recently, fire rated hinges did not have to have a visible label.
  • Fire rated components include hinges, lock/exit device, door closer, astragal, door coordinators, power transfer devices, glass lites and door viewers. In addition, any add-on components including door and jamb protection must be listed if they are to be mounted onto or into the surface of the door or jamb.

AMBICO manufactures specialty doors, frames, and windows.  Some of these specialty doors such as oversized doors (larger than commodity openings) may need to be fire rated.  However, doors like acoustic, blast, bullet, flood, lead lined or radio frequency meet different performance ratings.  Whereas doors like stainless steel, or bronze and brass clad, use special materials and construction.

All of these products are available fire rated in certain configurations and sizes. For detail regarding specific fire rating capabilities, please consult with our sales staff.

@AmbicoDoors #AmbicoDoors #Ambico

Company: Ambico

Product: Stainless Steel Assemblies

Source: https://www.ambico.com/blog/fire-rated-door-and-frame-assemblies/



Tags:

Doors

How to Get an Industrial Look with your Glass Wall Divider (November 30, 2022), Sensing solutions for hangar doors (September 19, 2022), The Pros and Cons of Fixed and Pivoting Glass Shower Shields (August 31, 2022), Add direct basement access to any home (fast, economical and convenient) (August 17, 2022), Physical Security in Layers: Turnstile Locations on a Corporate Campus (June 17, 2022), Attack Resistant Steel Doors and Frames (June 8, 2022), Bullet Resistant Steel Doors & Frames (August 25, 2021), Impact resistant entrances: introducing the 350/500 IR Water Performance Option, a watertight option from Kawneer (August 13, 2021), Glass door security options: developing an all-glass bulletproof door (February 15, 2021), Tempered Glass Sliding Door Designs for Your Office (January 18, 2021)

Fire Resistant

Backdraft and pressure relief dampers (January 31, 2023), Fire and Safety Protection in High-Traffic Student Spaces (January 11, 2023), Sheet lead: a quick and cost-effective method to efficiently shield radiation (December 16, 2022), 4 Innovative Fire Protection Technologies for 2022 (November 16, 2022), Automatic Smoke Vents protect property and aid firefighters (September 1, 2022), Not sure which elevator smoke curtain is the best for your product? Try out the Smoke Guard Product Selector! (August 5, 2022), 6 Common Places Fires in Buildings Begin (May 20, 2022), STC or OITC? How to select the proper sound rating for automatic smoke vents (March 21, 2022), Smoke Barrier and Partition Requirements: Everything You Need to Know (March 11, 2022), Glass Railing: Building Code Considerations (February 16, 2022)

Safety