About Column and Pipe Fitting Waterstop
Column and Pipe Fitting Waterstop
Earth Shield® has solved a long-standing problem for engineered concrete structures with circular protrusions, such as columns, pipes, piers, and pilasters. The problem: how to permanently seal the concrete joint when cast-in-place concrete forms against an existing circular member. The solution: Earth Shield® Column & Pipe Fitting (part no. JP320LC1.XX* [*XX is the diameter in inches]) manufactured with a flexible, chemical-resistant polymer and stainless steel anchoring hardware. A single laborer on the job site can quickly install the column fitting and its associated hardware. Just apply an epoxy gel bed to the existing surface; place the polymer ring into the epoxy gel bed; heat weld the single opening on the polymer ring using a waterstop splicing iron; and finally, complete the system with the stainless steel closure ring.
The Earth Shield® system functions as an internal dam, centrally located within the cast concrete, to stop aggressive chemicals, solvents, and hot petroleum oils from penetrating the joint. By preventing the passage of hazardous liquids, the Earth Shield® Column Fitting provides facility owners, engineers, and contractors with the necessary EPA-mandated containment compliance (EPA Title 40 CFR 265.193). Of course, the system prevents the passage of water as well. The mechanical properties of the polymer, plus the tear-web design of the JP320L profile, enable the column fitting to function equally well in expansion (isolation) joints and construction joints.
The Primary Choice for Secondary Containment ®” Call “The Waterstop Experts” at 800-821-3859 (951-763-7077)
Earth Shield® Column and Pipe Fitting Waterstop is available in many standard shapes and sizes.
Qualified technical assistance is available during any phase of your construction project.
Standard 3-part Specifications are available at our website in Microsoft Word and Adobe PDF format, and upon request in printed and a variety of computer word processor formats. Call our Technical Sales Staff for additional help with your specification.
Column and Pipe Fitting Waterstop
News
Brochures | 3-Part CSI specifications | CAD details
News archive:
How to Effectively Seal Circular Concrete Joints (May 16, 2023)
How to Effectively Seal Circular Concrete Joints (Nov 17, 2021)
Earth Shield Waterstop for Column and Pipe Fitting (Jul 04, 2019)
Free Engineering Webinar for PDH Credits: Waterstops for Liquid Tight Containment (Oct 26, 2014)
JP Specialties, Inc. : Waterstops For SPCC Compliance (Oct 14, 2012)
JPS Engineer Customers: Please Join Us for a Special Lunch and Engineering Seminar (Mar 27, 2012)
03150 - Concrete Accessories
03 15 00 - Concrete Accessories
03 15 13 - Waterstops