Industry-Leading Dampers from Ruskin Ideal for Data Center Environments
Other News Subscribe to FREE newsletter | Jan 22, 2021 |
Ruskin® announces air control dampers for data centers designed to maintain proper environmental conditions and ensure optimal performance of information and technology equipment.
New air control dampers for data centers from Ruskin® maintain proper environmental conditions and ensure optimal performance of information and technology equipment.
The CD50DC, CD60DC and TED50DC dampers also offer a new coupler option that joins two damper sections without a jackshaft. This allows an actuator to be mounted on the side of the
frame and deliver a narrow profile when space is limited. In addition, the DC models have enhanced operational performance with less moving parts on larger multi-section high sizes.
The CD60DC is available in galvanized steel, while the CD50DC and TED50DC are available in extruded aluminum.
“Air control dampers play a vital role in data centers and must consistently perform at optimal levels,” said Mike Coyazo, product manager, air control solutions, Ruskin. “These data center
models are designed with high-performing airfoil blades and meet stringent AMCA standards for leakage to ensure infrastructure reliability.”
All models provide the lowest AMCA leakage rating of 3 cfm/ft2 @ 1” w.g., which meets the requirements of the International Energy Conservation Code (IECC). The CD50DC features extruded aluminum airfoil blades for minimal pressure drop and a reinforced frame. The CD60DC includes one-piece roll-formed airfoil blades for minimal pressure drop and a robust uniframe design.
The TED50DC model offers superior overall performance, including thermal efficiency. Each blade has a break strategically placed between twin blade edge seals to eliminate thermal transfer and help reduce the potential for condensation.
To learn more about the new air control dampers for data centers, visit:
https://www.ruskin.com/model/cd50dc
https://www.ruskin.com/model/cd60dc
https://www.ruskin.com/model/ted50dc
An overview of the new data center dampers is also available in the Ruskin data center dampers flyer: https://www.ruskin.com/doc/Id/9520.
For more information about Ruskin, visit www.ruskin.com.
@ruskincompany #ruskincompany #AMCA #HVAC
For other relevant searches, you might want to try: