Stainless Steel Waterstop

Stainless Steel Waterstop

Earth Shield® Stainless Steel Waterstop can stop even the most corrosive fluids in their tracks, even at severely elevated temperatures. A variety of metals, grades, and gauges are available. Earth Shield® utilizes 20 gauge 316 low carbon as our standard alloy, which offers broad-spectrum corrosion resistance to most aggressive media, and is virtually untouched by the deleterious effects of ozone, making it an ideal choice for ozone contactor structures used in modern water treatment plants.

The Primary Choice for Secondary Containment ®” Call “The Waterstop Experts” at 800-821-3859 (951-763-7077)

Earth Shield® Stainless Steel Waterstop is available in many standard shapes and sizes, including profiles for new construction and retrofit. All change of direction fabrications can be pre-manufactured leaving only straight butt welding for the field.

Install Earth Shield® Stainless Steel Waterstop in all concrete joints. Waterstop should be centered in, and run the extent of the joint. All changes of directions should be prefabricated (see Shop Made Fittings), leaving only butt-welding for the field. Splices in stainless steel waterstops shall be welded using a TIG (recommended) or MIG process utilizing a welding rod to match the stainless (weld rod: 316ELC; diameter — .035 to .045). Repair damaged waterstops by removing damaged portions and patching. Patches shall overlap a minimum of 1 inch onto an undamaged portion of the waterstop. Weld all straight run material edge-to-edge (no overlapping). If installed in an expansion joint, assure backside (or open end of the center “V”) is covered completely with tape and the annulus (between tape and waterstop) is filled with 7/8” diameter backer rod before concrete pour. The tape and backer rod allows the center “V” to remain open allowing for joint movement. (Tape and backer rod is not necessary for non-moving contraction and construction joints.) More detailed installation instructions are in our Standard 3-part Specifications.

Qualified technical assistance is available during any phase of your construction project. 

Standard 3-part Specifications are available at our website in Microsoft Word and Adobe PDF format, and upon request in printed and a variety of computer word processor formats. Call our Technical Sales Staff for additional help with your specification.

News

News
Preview Summary Date URL
Stainless Steel Waterstop from JP Specialties Stainless Steel Waterstop from JP Specialties
Earth Shield® Stainless Steel Waterstop is available in many standard shapes and sizes, including profiles for new construction and retrofit. All change of direction fabrications can be pre-manufactured leaving only straight butt welding for the field.
Jul 20, 2023 URL

Brochures | 3-Part CSI specifications | CAD details

Brochures for Stainless Steel Waterstop

Brochures for Stainless Steel Waterstop
Preview Description Format Size Open
How to install Waterstop
Ribbed Waterstop Installation Guidelines, Retrofit Waterstop Installation Guides, Expansion Board Cap Waterstop Installation Guide, Base Seal Waterstop Installation Guides, Waterstop Welding Guide, Waterstop Welding Movies, Waterstop Splicing Iron Safety Manual and Users Guide, Waterstop Split Forming, How to Install Type NB190®, How to Install Labyrinth Waterstop, How to Install Split Ribbed Waterstop, Carbon Steel Waterstop Installation Guidelines, ...
PDF 11 kB Open
Waterstop Chemcart
Waterstop Chemcart
PDF 493 kB Open
Waterstop eBook
Concrete is everywhere: Buildings, fountains, parking decks, locks and dams, roads and bridges, and myriad other constructions. Because of its long lifespan, high workability, and near-worldwide availability, concrete is the preferred building material for large structures, especially those subject to hydraulic pressure. Not all concrete structures require protection from the ingress of water or other fluids, but those that do require a properly installed waterstop in and along their concrete joints. The concrete joint is the most likely point of leakage and waterstops are uniquely designed to prevent this. This book’s sole purpose is to educate the reader on all facets of waterstop.
    Open

3-Part CSI specifications for Stainless Steel Waterstop

3-Part CSI specifications for Stainless Steel Waterstop
Description Format Size Download
Safety Data Sheets
Safety Data Sheets (SDS) for Earth Shield Waterstop Products
  8 kB Download

CAD details for Stainless Steel Waterstop

CAD details for Stainless Steel Waterstop
Preview Description Format Size View Download
Waterstop CAD
Waterstop CAD (pdf, dwg)
PDF/DWG 40 kB   Download


Request for Information / Request a Catalog from JP Specialties, Inc. about Stainless Steel Waterstop
 
(Please check companies and/or products above.)
 
*Name:    
*Email:    
Company:    
*Type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     


News archive:
Waterstops for Fuel Storage (Jan 08, 2017)
Earth Shield Stainless Steel Waterstop for Buncefield Reconstruction from JP Specialties Inc. (Jan 11, 2015)
Waterstops for Fuel Storage (Feb 24, 2014)
JP Specialties: Download the free reference manual on Waterstop used in concrete joints (Feb 28, 2013)
Earth Shield® Is Proud To Announce The Addition Of Fully-rendered, Isometric CAD Details (Aug 23, 2012)
JP Specialties To Supply For SunEdison (Aug 03, 2012)
JP Specialties: In Case You Missed the City Club Seminar (May 23, 2012)
Earth Shield Waterstop Profiles now all with factory installed brass eyelets (Oct 03, 2009)
New Retrofit Waterstop Profile Accommodates Large Joint Movements (Feb 20, 2009)

03150 - Concrete Accessories
03250 - Post-Tensioning
03380 - Post-Tensioned Concrete
07130 - Sheet Waterproofing
07150 - Sheet Metal Waterproofing
07620 - Sheet Metal Flashing and Trim
07630 - Sheet Metal Roofing Specialties
03 15 00 - Concrete Accessories
03 15 13 - Waterstops
03 38 00 - Post-Tensioned Concrete
07 11 19 - Sheet Dampproofing
07 13 00 - Sheet Waterproofing
07 15 00 - Sheet Metal Waterproofing
07 62 00 - Sheet Metal Flashing and Trim
07 63 00 - Sheet Metal Roofing Specialties