General
This specification is for use over any type of approved structural deck
(without insulation) which can receive and adequately retain nails or other types of mechanical fasteners that may be recommended by the deck manufacturer. Examples of such decks are wood and plywood. This specification is not for use directly over lightweight, insulating concrete decks.Design and installation of the deck and/or substrate must result in the
roof draining freely and to outlets numerous enough and so located as to remove water promptly and completely. Areas where water ponds for more than 24 hours are unacceptable and are not eligible to receive a JM Roofing Systems Guarantee.Note: All general instructions contained in the current JM Commercial/
Industrial Roofing Systems Manual should be considered part of this specification. FlashingsFlashing details can be found in the "Bituminous Flashings" section of the
JM Commercial/Industrial Roofing Systems Manual. ApplicationOver wood board decks, one ply of sheathing paper must be used under
the base felt and on top of the wood board deck.Note: On roof decks with slopes up to 1" per foot (83.3 mm/m), the roofing
felts may be installed either perpendicular or parallel to the roof incline. On slopes over 1" per foot (83.3 mm/m), refer to Paragraph 6.11 of this section for special requirements.Using GlasBase, GlasBase Plus, PermaPly 28 or Ventsulation, start with
a 12" (305 mm) width (a specific base sheet may be a condition of Guarantee). The following base sheet courses are to be applied full width, lapping the preceding felt 2" (51 mm) on the side laps and 4" (102 mm) onthe end laps. Nail the side laps 9" (229 mm) o.c. Down the longitudinal
center of each felt, place two rows of nails spaced approximately 11" (279 mm) apart, with the nails staggered on approximately 18" (457 mm) centers. Use nails or fasteners appropriate to the type of deck with 1" (25 mm) minimum diameter caps. For additional fastener information, refer to the Fastener Data in the "Roof Deck" section of the current JM Commercial/Industrial Roofing Systems Manual.Using GlasPly Premier or GlasPly IV, apply a piece 18" (457 mm) wide, then
over that, a full width piece. The following felts are to be applied full width overlapping the preceding felts by 19" (483 mm) so that at least 2 plies of felt cover the base felt/substrate at all locations. Install each felt so that itis firmly and uniformly set, without voids, into the hot asphalt (within �25�F
[�14�C] of the EVT) applied just before the felt at a nominal rate of 23 lbs.per square (1.1 kg.m2) over the entire surface. SurfacingFlood the surface with the appropriate asphalt at an approximate rate of
60 lbs. per square (2.9 kg/m2). Into the hot asphalt, embed an acceptable gravel at a rate of 400 lbs. per square (19.5 kg/m2) or an acceptable slag at a rate of 300 lbs. per square (14.6 kg/m2). Aggregate must be installed so that there is complete coverage across the entire surface and at least 50% of the aggregate is solidly adhered in the hot asphalt. Aggregate should meet the requirements of ASTM D 1863. AsphaltAsphalt should meet the requirements of ASTM D 312.
JM Guarantees require the use of Trumbull asphalt or another JM
Approved Asphalt. The Contractor must provide an Asphalt Confirmation Number (ACN) on projects which require a JM Guarantee. The ACN willindicate that the asphalt was registered with the approved asphalt
source.Check with a JM Technical Services Specialist for special asphalt
requirements in hot climates.
For an identical copy of this specification, ask for RS-2039.