SPECIFICATION DATA

56_5013a.jpg (16770 bytes)

BENEFITS

  • Flexible Security�Area controlled security protects against both external and internal theft by securing some areas while others are occupied.
  • Adaptability to Building Use�A shared area may be armed or disarmed to allow access to common areas. The system can also require the arming of critical areas before the main system is armed.
  • Cost Effectiveness�Burglary, fire, hold-up, critical equipment monitoring, and other services are monitored from one control at one affordable price.
  • Ease of Use�Arming and disarming is simple with the ALL ON/ OFF key. Disarming can be as simple as presenting an access credential to gain entry.
  • Employee Control�Authority levels control who operates the system, what they can do and what doors they can use.
  • Honeywell Monitoring�The Honeywell Customer Service Center assures reliable and prompt response to alarm conditions.
  • Approvals�The Intelliguard System is listed by the required approval agencies�your assurance that it meets the highest industry standards.
  • Tailored Security�Tailored areas, control centers, command lists, and displays match your system to your building operation.

The Honeywell Intelliguard "area controlled" security system protects against internal and external theft. With the Intelliguard system, up to eight different areas of a facility can be individually armed and disarmed in order to provide security in one area while other areas are occupied.

Intelliguard areas are designed to match specific business needs and routines. A hallway or vestibule shared by several security areas can be automatically turned on or off to assure easy access to other protected areas. The system can also be  programmed to require that a certain critical area be turned on before the entire system is armed.

The flexibility of the Intelliguard system allows the monitoring of several types of protection such as burglary, fire, sprinkler supervision, hold-up and critical equipment, on the same control and at one affordable price.

The Intelliguard system can be equipped to pinpoint the exact location of an alarm, ensuring a more accurate response to an emergency. Additionally, repeated false alarms are minimized because the source of the problem is identified and can be fixed the first time.

Honeywell has designed a family of control centers to meet every customer�s needs. Control centers are used to display system status, and can perform a variety of system commands such as arming or disarming all areas at once, arming or disarming one area at a time, and arming or disarming an area perimeter. The control centers utilize function keys that provide simple, yet flexible, features such as the ALL ON/OFF key that makes arming and disarming effortless. The control centers also provide access to a tailored command list, showing users only those commands they might need.

Employees are assigned a user passcode with its own authority level. Passcodes with authority levels provide security against unauthorized use. A passcode must be used to initiate any system command. Employees may also be issued an access credential used to unlock the door and disarm the security system.

An Intelliguard system monitored by Honeywell�s Customer Service Center enhances property protection because the fire or police department is quickly dispatched in response to an alarm signal. Intelliguard has received approvals from the required agencies, providing assurance that it meets all industry standards.

 

FEATURES

Area Controlled Security�A business can protect against external and internal theft because up to eight different areas of a facility can be armed and disarmed independently in order to provide security in one area while others are occupied.

Shared/Master/Associate Areas�An area can be shared by several security areas so it is automatically turned on when other associated areas are armed. Alternately, an area can be a master area that requires critical areas to be armed before it can be armed.

Individual Points of Protection�The system can be equipped to pinpoint individual doors, windows, fire detectors, or other sensors.

Point Bypass�Designated points of protection can be bypassed before the system is armed in order to permit continued protection for remaining points. Specific points can be given priority status to prevent bypass.

ALL ON/OFF Key�This key provides a simple method to arm and disarm all areas assigned to the user.

Entry Control�Optional credential readers control access to an area. Entry can also cause the system to disarm or simply turn off the interior protection.

Perimeter Arm�Employees who work late can arm the building�s perimeter while the interior protection remains disarmed. When employees leave for the night, they can conveniently switch to complete protection with the ALL ON/OFF key without having to disarm.

Day Annunciation�Designated protection points can sound a local alarm during business hours to help prevent internal theft through doors in remote parts of a facility.

Watch Mode�The system can be programmed to automatically sound a short tone from the control center when a point is faulted. This alerts occupants to someone entering or leaving an area when the system is disarmed.

Passcode Access�A personal passcode must be entered each time the system is operated in order to prevent unauthorized use. An event log automatically records the actions of each user to provide an audit trail.

Authority Levels�One of fifteen authority levels is assigned to each user for each area. The authority level determines the commands a user can issue and what doors they can use for entry control.

Duress Signaling�Users can inconspicuously advise the Honeywell Customer Service Center of a problem in the event they are forced to deactivate the system.

English Language Display�The optional 540, 541 and 542 Control Centers have a 16-character alphanumeric display that helps guide the user through system operation. Clear messages show system status, confirm commands, and give instructions.

Tailored Command List�The system provides a customized list of commands, in the order you would like, according to the user and area.

One Person Walk Test�During the Walk Test mode, points tested are automatically stored. The Control Center displays a list of points, tested and untested, which allows one person to check the operation of all protection devices. Periodic testing provides assurance that the system is operating properly.

LED Display�The optional 550 Control Center has an LED display showing the status of up to eight points (normal, bypassed or alarm memory). Other LED indicators show armed status and power status to help determine the condition of the system at a glance.

Local Printer�Optional printer(s) provides on-premise recording of system events. The record includes time, date, event, area number, user number, point number and explanatory text.

High Speed Digital Communicator�The communicator provides low-cost means of signaling the Honeywell Customer Service Center in order to ensure a prompt response to alarm and other system messages.

 

SPECIFICATIONS

Equipment Dimensions in in. (tall x wide x deep):
D5591 Standard Enclosure: 16.0 x 16.0 x 3.5
D8108AH Attack Resistant Enclosure: 16.0 x 16.0 x 3.5
D8109H Red Fire Enclosure: 16.0 x 16.0 x 3.5
D9210BH Entry Control Module Enclosure: 5.0 x 8.0 x 2.5
WSE 4205W Credential Reader: 5.75 x 5.25 x 1.25
D8127/9127 Point Terminal: 3.2 x 1.5 x 0.9
Control Centers: 4.5 x 8.5 x 0.9

Control Center Models:
540 Control Center�16-character alphanumeric display
541 Fire Control Center�Fire function keys and alphanumeric display
542 Fire Annunciator�16-character alphanumeric display
550 LED Area Control Center

Electrical:

    Input:
        Primary: 16.5 Vac, 40 VA class II plug-in transformer
        Secondary: 12 Vdc 7-14 Ah, rechargeable battery

    Output:
        Continuous: 12 Vdc 1.4A maximum
        Alarm: 12 Vdc 2.0A maximum

    D9210 Lock Relay Rating:
        spdt 2.0A @ 12/24 Vdc

Environmental:
   Operating temperature: 32° to 122°F (0° to 50°C)

Approvals:
   UL Central Station, Mercantile and Proprietary
    UL Fire (NFPA 72)
    California State Fire Marshal
    New York City�MEA
    DOD (SCIF)

Model Comparisons

Features

5800

5900

Control Centers

8 Supervised
32 Unsupervised

8 Supervised
32 Unsupervised

Alarm Inputs (points)

74

245

Relay Outputs

51

131

Custom Commands

4

16

Printers

1

3

Entry Control Doors

4

8

Users

100

250

Credentials

400

1000

redletterlogo.JPG (4746 bytes)


Helping You Control Your World

Home and Building Control Honeywell Inc.

Honeywell Plaza
P.O. Box 524 Minneapolis, Minnesota 55408-0524

Honeywell Latin American Region

480 Sawgrass Corporate Parkway
Suite 200
Sunrise, FL
33325

Honeywell Limited - Honeywell Limitée

155 Gordon Baker Road
North York, Ontario

M2H 3N7

Honeywell Europe S.A.

3 Avenue du Bourget
B-1140 Brussels
Belgium

Honeywell Asia Pacific Inc.

Room 3213-3225
Sun Hung Kai Centre
No. 30 Harbour Road
Wanchai, Hong Kong