Rolling Doors\Rolling Service. CSI 3-Part Specifications.
Rolling Service Door Specifications
Part 1 - General
1.01 Work Included
Doors shall be Raynor Rolling Steel Service Doors as manufactured by Raynor Garage Doors of Dixon, Illinois.
1.02 Furnish and Install
All Rolling Steel Service door work including electrical operators, controls, and accessories as shown on the drawings and herein specified.
1.03 Related Work
Opening preparation, structural metal work, access panels, finish or field painting, field electrical wiring, wire, conduit, fuses, and disconnect switches are in the scope of the work of other divisions or trades.
Part 2 - Product
Series SC, LC, FF, IF, AF, AI, FP, AP
2.01 Curtain
Lateral movement of the slats to be contained by means of cast-iron galvanized end locks fastened to the ends of every other slat with zinc-plated steel rivets. Windlocks shall be provided as required by door size or special windload requirements. Windlocks to be galvanized cast-iron and fastened with zinc-plated steel rivets.
Steel Slats
Shall be commercial quality hot-dipped galvanized (G-90) steel per ASTM A-924
and ASTM A-653. Painted with an epoxy primer and a finished gray polyester.
Bottom bar shall be two steel angles, minimum 1 1/2" x 1 1/2" x 1/8" (38.1MM x
38.1MM x 3.2MM). Single contact type bottom astragal.
Aluminum Slats
Shall be 5005H34 etch and anodized on both sides to 201R1. Bottom of curtain
shall be reinforced with an aluminum extruded T-shaped bar. Single contact type
astragal.
Perforated Slats
Shall be punched with a series of 1/16" (1.6MM) diameter holes across their entire
length which will provide 31% open area per square foot of door.
2.02 Slats
A. Series SC (Small "C" Slat) and LC (Large "C" Slat)
The curtain shall consist of steel interlocking countour slats not less than 22
gauge.
B. Series FF (Flat Slat) and FP (Flat Perforated Slat)
The curtain shall consist of steel interlocking flat slats not less than 22 gauge.
C. Series AF (Aluminum Flat Slat) and AP (Aluminum Flat Perforated Flat
Slat)
The curtain shall consist of aluminum interlocking flat slats not less than .04"
thick.
D. Series IF (Insulated Flat Slat)
The curtain shall consist of steel interlocking flat slats not less than 22 gauge
with 3/4" (19.1MM) thick, expanded polystyrene core included with the entire
length of each slat. Interior surface shall be a 24 gauge, primed painted,
hot-dipped galvanized steel cover. The door shall be provided with vinyl jamb
seal and rubber hood baffle as standard. The curtain "U" value is .24 and "R"
value is 4.1 (These specifications reflect calculated characteristics of core
material).
E. Series AI (Aluminum Insulated Flat Slat)
The curtain shall consist of aluminum interlocking flat slats not less than .04"
thick with 3/4" (19.1MM) thick, expanded polystyrene core included with the
entire length of each slat. Interior surface shall be extruded aluminum .05"
thick. The door shall be provided with a vinyl jamb seal and rubber hood
baffle as standard. The curtain "U" value is .24 and "R" value is 4.1 (The
specifications reflect calculated characteristics of core material).
Independent test results provided in accordance with ASTM C-236 are
available on request.
2.03 Guides
All guide assemblies shall be fabricated from three structural steel angles. Guide angles shall be minimum 3" x 2" x 3/16" (76.2MM x 50.8MM x 4.8MM) and fitted with two removable curtain stops each. Wall mounted angles shall be continuous type.
2.04 Brackets
Mounting bracket plates shall be made from a minimum 3/16" (4.8MM) steel plate and attached to the wall angle of the guide assembly with 1/2" (12.7MM) diameter class 5 hardened bolts. The drive side bracket shall be fitted with a sealed ball bearing.
2.05 Barrel
The barrel shall be made from a minimum 4 1/2" (114.3MM) O.D. x .120 (3.1MM) wall structural steel pipe. Deflection of pipe under full load shall not exceed .03" (.8MM) per foot of span.
2.06 Counterbalance
The curtain shall be counterbalanced by means of oil tempered, helical torsion springs, grease-packed and mounted on a single continuous steel torsion shaft. Springs shall be compression spring design to facilitate any counterbalance maintenance.
2.07 Hood
Hood shall be 24 gauge prime painted, hot-dipped galvanized steel with rolled edges.
2.08 Operation
Manual operation to be provided with inside lift handle and locking bar, padlocks by others. Not recommended for doors over 10' (3048MM) wide and/or over 7'4" (2235MM) high. IF series not to exceed 8' (2438MM) wide or 7'4" (2235MM) high. Chain hoist or motor operation recommended on all doors requiring heavier than standard gauge. Chain operation shall be by means of reduction gears and galvanized hand chain. (Motor operation available).
2.09 Windload
Series SC, LC, FF, IF
Doors shall be designed to withstand 20 pounds per square foot (97.64 Kg./Sq.M.) windload. Optional windloads are available.
2.10 Finish
All non-plated components of the door shall receive one coat of rust-inhibitive primer.
2.11 Warranty
The Raynor Rolling Steel Service Door and it's components shall be free from defects in material and workmanship for a period of one year from the date of delivery to the original purchaser.
Part 3 - Execution
3.01 Installation
Raynor Rolling Steel Service Doors shall be installed by an authorized Raynor Garage Door Distributor.