Part 1: General

1.1 Scope

Specify areas to receive this acoustical treatment.

1.2 Qualifications

Construction conditions shall comply with ASTM C636. Acoustical

material and suspension systems, including all necessary

hangers, grillage, splines and supporting hardware, shall be

furnished and installed by an acoustical contractor.

1.3 Delivery and Storage of Materials

All materials shall be delivered in their original unopened

packages and stored in an enclosed shelter providing protection

from damage and exposure to the elements. Damaged or

deteriorated materials shall be removed from the premises.

Immediately before installation, tile and panels shall be stored

for a sufficient time to stabilize temperature and humidity

conditions ambient during installation and anticipated for

occupancy.

1.4 Environmental Conditions

Installation of ACOUSTONE and AURATONE acoustical tile and

panels and suspension systems shall not begin until building is

enclosed, permanent heating and cooling equipment is in

operation, and residual moisture from plaster, concrete or

terrazzo work has dissipated. Installation of Gypsum Lay-in

panels shall not begin in an exterior application until

protection from direct exposure to water and weather has been

provided. ORION and ECLIPSE ceiling products and PREMIER glass

fiber ceiling panels can be installed and used in temperature

and humidity conditions up to 90 degrees F, no more than 90% RH.

1.5 Design Conditions

Systems shall be rated NRC ( ) in accordance with ASTM C423 and

STC ( ) in accordance with AMA 1-II as tested by an independent

agency.

Part 2: Products

2.1 ECLIPSE

ECLIPSE mineral fiber ceiling (panels) (FIRECODE panels,

approved for UL Design No. [ ]) (tile) (FIRECODE tile, approved

for UL Design No. [ ]), by USG Interiors, Inc., ( ) item number,

( ) color, ( ) size, ( ) edge, NRC range ( ), STC range ( ).

Note to specifier: Refer to product descriptions for pattern,

item number, color, size, edge, NRC and STC options.

2.2 ORION

ORION (210) (220) (270) mineral fiber ceiling (panels) (FIRECODE

panels, approved for UL Design No. [ ]), by USG Interiors, Inc.,

having laminated (Nubby fabric) (vinyl) surface, ( )pattern, (

) item number, ( ) color, ( ) size, ( ) edge, NRC range ( ), STC

range ( ).

Note to specifier: Refer to product descriptions for pattern,

item number, color, size, edge, NRC and STC options.

2.3 ACOUSTONE

ACOUSTONE molded mineral fiber (tile) (FIRECODE tile, approved

for UL Design No. [ ]) (panels) (FIRECODE panels, approved for

UL Design No. [ ]), by USG Interiors, Inc., free of mechanical

perforations, non-breathing factory-applied foil backing ( )

pattern, ( ) item number, ( ) color, ( ) size, ( ) edge, NRC

range ( ), STC range ( ).

Note to specifier: Refer to product descriptions for pattern,

item number, color, size, edge, NRC and STC options.

2.4 AURATONE

AURATONE water-felted mineral fiber (tile) (FIRECODE tile,

approved for UL Design No. [ ]), (panels), (FIRECODE panels,

approved for UL Design No. [ ]), by USG Interiors, Inc., (

)pattern, ( ) item number, ( ) color, ( ) size, ( ) edge, NRC

range ( ), STC range ( ).

Note to specifier: Refer to product descriptions for pattern,

item number, color, size, edge, NRC and STC options.

2.5 Special-Function

AURATONE (FIRECODE) special function products by USG Interiors,

Inc., ( ) item number, ( ) color, ( ) size, ( ) edge, NRC range

( ), STC range ( ):

2.5.1 Abuse Resistant

FIRECODE panels, approved for UL Design No. ( ), (ROCK FACE

pattern) (IMPACTION System).

2.5.2 Environment-Resistant

FIRECODE panels, approved for UL Design No. ( ), (CERAMIC

HERITAGE) (METAL FACE [perforated] [unperforated]) (SUPER-E

[perforated] [unperforated]) pattern.

2.5.3 Sanitary Condition

FIRECODE panels, approved for UL Design No. ( ), CLEAN ROOM

pattern (Class 100, unperforated) (Class 10,000-100,000,

perforated)

2.6 Gypsum Ceiling Panels

FIRECODE core Gypsum Lay-in panels by USG Interiors, Inc., ( )

item number, unit facing (white vinyl stipple pattern)

(unfinished paper) (painted), ( ) size, square edge.

2.7 Extra Sound Absorbent

PREMIER glass fiber substrate panels by USG Interiors, Inc., ( )

item number, ( ) size, ( ) edge, (Nubby) (Twill) (Kapok)

laminated facing, ( ) NRC, in white color.

Note to specifier: Refer to product descriptions for pattern,

item number, color, size, edge, NRC and STC options.

2.8 Fire Rating Accessories

By USG Interiors, Inc.

2.8.1 THERMAFIBER Light Fixture Protection, (box) (tent)

(vented-box) type assembly approved for UL Design No. ( ), of

semi-rigid spun mineral-fiber board, nom. 1 1/4" thick , unfaced

and unbacked.

2.8.2 THERMAFIBER Fire Protection Batts

Approved light-fixture protection field-fabricated to UL Design

No. ( ) requirements from flexible spun mineral-fiber mats, 1

1/2" thick, unfaced and unbacked.

2.9 Sound Rating Accessories

THERMAFIBER SAFB insulation of spun mineral-fiber, semi-rigid

mats with square-cut edges, unfaced and unbacked, by USG

Interiors, Inc.:

2.9.1 Installed Over Partition Stud Cavities

(1 1/2) (3)" x 2' x 4' sizes, (single-layer on entire ceiling)

(double-layer on ceiling in 8'-wide strips centered on

partitions).

2.9.2 Installed as Plenum Barriers

3" x 2' x 4' sizes, of (vertical) (inverted "T") (tent) type.

2.9.3 Overlaid on Ceiling

1 1/2" x 2' x 4' sizes, (single-layer on entire ceiling)

(double-layer on ceiling in strips extending 4' to each side of

partitions).

2.10 DONN Suspension Systems

By USG Interiors, Inc.:

2.10.1 Fire-Rated Concealed Suspension

Meeting ASTM C635. (DX tee system with splines that engage

adjacent tile.) (RIGID X tee system with screw-applied gypsum

board.)

2.10.2 Fire-Rated Exposed Suspension

(DXL) (CENTRICITEE DXLT) (FINELINE DXLF) (Environmental ZXLA

Grid system), per UL Design No. ( ), all main and cross tees

meeting "intermediate" or "heavy" duty classifications of ASTM

C635, ( ) color.

2.10.3 Class A Exposed Suspension

Meeting "intermediate" or "heavy" duty main tee structural

standards of ASTM C635, ( ) color.

2.10.4 Corrosion-Resistant Exposed Suspension

(DXLA) (Highline) (Environmental ZXA Grid System) (Environmental

AX Grid System), ( ) color.

2.10.5 Narrow 1/8" Reveal Geometrix Suspension

(GTX) accepts Geometrix or Fine Fissured panels, ( ) color.

Note to specifier: Refer to product descriptions for pattern,

item number, color, size, edge, NRC and STC options.

Part 3: Execution

3.1 Suspended

Install acoustical material and suspension system, including

necessary hangers, grillage, splines and other supporting

hardware, in accordance with ASTM C636, all code requirements

and sound industry practice (such as CISCA guidelines).

3.2 Adhesive

Apply tile with an adhesive manufactured specifically for this

purpose, in accordance with manufacturer's directions, and/or as

follows. Brush off any loose dust from tile back surfaces and

prime them where adhesive is to be applied. This lays down any

residual dust to assure good adhesion. Prime only a 2-3" circle

near each corner by buttering a very thin coat of adhesive with

trowel blade at a 45 degree angle. Then apply a walnut-sized

dab of adhesive to each of the 4 circles and press tile firmly

in place. Insert splines in kerfs at corners of units. Foil-

backed ACOUSTONE tile should not be adhesively applied.

3.3 ACOUSTONE "F" Fissured Tile

Intermix tile from 4 or more cartons to obtain uniform

distribution of fissure variations.

3.4 The ILLUSION Ceiling Series Exposed Grid Suspension

Install inverted tee, direct-hung, exposed surface system having

low-gloss finish and color of the ILLUSION Ceiling Series.

System should meet "intermediate" or better structural standards

of ASTM C635.

3.5 Fire-Rated Suspension

Install suspension per UL Design No. ( ) and ASTM C636.

3.6 Light Fixture Protection

Install light fixture protection and necessary hangers and ties

in accordance with UL Design No. ( ) and ASTM C636.

3.7 Ceiling Sound Insulation

Lay blankets flat on ceiling panels and tightly fit around all

grillage, hangers and other vertical penetrations:

3.7.1 Single-Layer

Over entire ceiling.

3.7.2 Double-Layer

3" total thickness, over that part of ceiling extending 48" on

each side of all partitions.

3.8 Plenum Sound Barriers

Install THERMAFIBER blankets; cut vertical blankets as necessary

to clear plenum obstructions:

3.8.1 Upside Down "T"

Lay horizontal blankets on ceiling grid extending 1' on either

side of partition centerline and lean vertical blankets against

hanger wires for support.

3.8.2 Vertical Barrier

Lean vertical blankets against hanger wires for support over

partition centerline.

3.8.3 Tent Barrier

Lean blankets together over partition centerline and wire or

clip tops together.